Calibration Verification Fluids (with BUN)

The complete Linearity Verification Material (LVM) for the epoc® Blood Analysis System with BUN.

Description

The complete Linearity Verification Material (LVM) for the epoc® Blood Analysis System offering:

- pH, gases, electrolytes and metabolites in one ampule.

- Five levels covering the physiologically relevant range.

- Convenience of using only one epoc cartridge for each level.

- Optimization for epoc with physiological target values.

Intended Use

Eurotrol Calibration Verification Fluids for Epocal is an assayed blood gas, electrolyte and metabolite reference material, to verify precision, accuracy, and linearity of the epoc Blood Analysis System. Eurotrol Calibration Verification Fluids is also developed to verify calibration, operating temperature and other performance characteristics. Eurotrol epoc® GAS-ISE Metabolites is designed to test the following analytes: pH, pO2, pCO2, Na+, K+, Ca2+, Mg2+, Cl-, glucose, lactate, urea, creatinine and tCO2

Analytes

ARTICLE CODE
267.000.005
Level 1
Level 2
Level 3
Level 4
Level 5
pH
6.995 - 7.115
7.384 - 7.504
7.660 - 7.780
6.617 - 6.737
7.813 - 7.933
1
pO2
52.2 - 83.8
94.3 - 125.9
160.1 - 216.7
31.1 - 62.7
468.2 - 702.4
mmHg
pCO2
64.2 - 81.8
25.0 - 40.0
15.9 - 30.9
100.0 - 144.0
0.0 - 10.6
mmHg
tCO2
15.5 - 27.5
16.2 - 28.2
24.1 - 36.1
10.6 - 22.6
0.0 - 10.4
mmol/L
Na+
106.0 - 118.0
135.0 - 147.0
164.0 - 178.0
79.0 - 91.0
173.0 - 187.0
mmol/L
K+
1.8 - 2.6
3.0 - 4.8
5.5 - 6.7
7.3 - 8.5
10.2 - 11.6
mmol/L
Ca2+
1.35 - 1.69
1.03 - 1.19
0.53 - 0.67
3.12 - 3.90
0.25 - 0.39
mmol/L
Cl-
75.0 - 85.0
91.0 - 105.0
105.0 - 121.0
59.0 - 67.0
128.0 - 156.0
mmol/L
Glu
25.0 - 43.0
89.0 - 119.0
206.0 - 322.0
12.0 - 30.0
495.0 - 773.0
mg/dL
Lac
0.6 - 1.2
2.3 - 3.7
5.0 - 7.9
0.2 - 0.8
11.9 - 23.6
mmol/L
Crea
25.0 - 104.0
118.0 - 197.0
235.0 - 370.0
0.0 - 0.8
852.0 - 1692.0
µmol/L
Urea
16.1 - 21.1
4.6 - 6.8
0.7 - 2.9
31.9 - 47.6
0.4 - 2.5
mmol/L
BUN
45.00 - 59.00
13.00 - 19.00
2.00 - 8.00
89.00 - 133.00
1.00 - 7.00
mg/dL
All ranges per analyte are target ranges for manufacturing of the product. See actual value sheets with lot specific values, which may vary in range widths and mean values due to instrument chosen for value assignments.

Details

Container
Filling
Box
Storage Temperature
Shelf-life
Ampoule
2.5 ± 0.1 mL
5 per Box
Unopened 2 - 8 °C
Opened N/A
Unopened 365 days
Opened After opening the ampoule, it is stable for 30 seconds.

Documents

Videos

CueSee® Online

Ordering

Online ordering will be available soon, in the meantime you can contact us.
Level
Packaging
Article code